Medium-Voltage Switchgear
IEEE C37.20 compliant and fully compartmentalized. Provides high fault tolerance and core-level protection for medium-voltage grids.
-
Core Capabilities
-
Lead Time: 10-14 Weeks. Serving as the definitive Short Lead Time Switchgear solution, we successfully bypass the 60+ week industry bottleneck.
-
Comprehensive Code ComplianceNative compliance engineered to the latest editions of North American electrical codes, including NFPA 791-R2024. Our structural and electrical designs strictly adhere to IEEE C37.20.2-2022 and IEEE C37.20.3-2023, alongside UL 347. For Canadian deployments, our manufacturing and evaluation processes fully encompass SPE-1000-21 and CSA C22.2 No.31:23 standards.
-
Core TechnologyFully compartmentalized IEEE C37.20.2 Metal-Clad Switchgear design with premium Draw-out Vacuum Circuit Breakers (VCBs).
-
Fail-Safe Interlocking SystemIntegrated mechanical and electrical interlocks prevent high-risk operating errors, including racking a breaker under load or closing a grounding switch onto an energized circuit.
-
Medium-Voltage Switchgear
Benefits
True metal-clad construction. Independent, grounded metal compartments for the breaker, main bus, and cables prevent arc flash propagation.
Equipped with highly reliable, draw-out vacuum circuit breakers for fast arc quenching and extremely low maintenance.
Seamless integration with industry-standard protective relays (e.g., SEL, GE, ABB) tailored to your specific grid or BESS requirements.
Factory assembled, pre-wired, and rigorously FAT-tested to dramatically reduce expensive field labor and commissioning time.
Technical Specifications
| Parameter | Value |
|---|---|
| Rated Maximum Voltage | 5 kV Class: 4.76 kV; 15 kV Class: 15.0 kV; 38 kV Class: 38.0 kV |
| Lightning Impulse Withstand (BIL) | 5 kV Class: 60 kV; 15 kV Class: 95 kV; 38 kV Class: 150 kV |
| Main Bus Continuous Current | 5 kV Class: 1,200A – 3,000A; 15 kV Class: 1,200A – 4,000A; 38 kV Class: 1,200A – 3,000A |
| Short-Circuit Current Rating | 5 kV Class: 31.5 kA – 50 kA; 15 kV Class: 31.5 kA – 63 kA; 38 kV Class: 31.5 kA – 40 kA |
| Breaker Type | Draw-out VCB |
| Arc-Resistant Option | IEEE C37.20.7 (Type 2B) |
| Enclosure & Finish | NEMA 1 (Indoor), NEMA 3R (Outdoor) |
| Lead Time & Warranty | 10-14 Weeks |
Dedicated Engineering Support
Powering high-load applications requires precise planning. Send your exact single-line diagram (SLD) to our heavy-power engineering team so we can confirm breaker coordination and compliance requirements.