Single-Phase Pad-Mounted Transformer
DOE 2016 compliant and tamper-resistant. Delivers reliable drop-in power for distributed renewable networks and commercial EPC projects.
-
Core Capabilities
-
Engineered with premium 100% copper windings and manufactured end-to-end within our own facilities, our single-phase pad-mounts operate as a highly reliable IEEE C57.12.00 Liquid-Filled Transformer, helping general contractors effectively overcome traditional supply chain delays. Featuring robust NEMA 3R enclosures and a dead-front design, they are purpose-built for safe outdoor installation in retail centers, residential complexes, and distributed solar arrays, integrating seamlessly into 60Hz or 50Hz distribution networks. To ensure unquestionable compliance and safety, these units are manufactured and evaluated in strict accordance with NFPA 791-R2024, IEEE C57.12.00 -2021, and the IEEE C57.12.90-2021 test code. For Canadian deployments, our systems fully comply with SPE-1000-21, CSA C2.1:24, and the specific CSA 227.3:25 standard. Backed by comprehensive cULus system listings (e.g., UL-CA-2228369-0, UL-US-2402197-0, UL-US-2586027-0), they guarantee frictionless approval by the local Authority Having Jurisdiction (AHJ) during turnkey commissioning.
-
High-EfficiencyOperating at a standard 65°C temperature rise, our precision core designs strictly minimize operational energy losses, optimizing the Return on Investment (ROI) for commercial clients.
-
Rigorous Testing & Comprehensive CertificationEvery unit is subjected to 100% Factory Acceptance Testing (FAT) and arrives on-site with factory-applied cULus labels, eliminating regulatory risks and compliance-related engineering delays at the source.
-
Eco-FriendlyAvailable with the FR3™ natural ester dielectric fluid upgrade, providing exceptional fire safety for densely populated commercial spaces while delivering on environmental commitments with 100% biodegradability.
-
-
-
-
Single-Phase Pad-Mounted Transformer
Benefits
A highly controlled 8-week delivery window ensures general contractors meet handover dates, significantly mitigating the risk of Liquidated Damages (LDs).
Finished with ANSI C57.12.28 compliant anti-corrosion coatings, the NEMA 3R enclosure provides long-lasting defense against harsh weather and environmental degradation.
100% copper winding and core configurations easily manage dynamic loads, backed by an industry-leading 36-month warranty.
Equipped standard with lifting lugs, drain valves, and pressure relief valves (PRVs). Field installation is reduced to simply setting the unit in place and terminating the utility feed.
Technical Specifications
| Parameter | Value |
|---|---|
| Capacity Range | 50 kVA to 250 kVA (Scalable up to 500 kVA) |
| Primary Voltage | 7.62kV, 12kV, 15kV, 35kV |
| Secondary Voltage | 120/240V, 277V, 416V, 480V, 600V (Custom configurations available up to 24.94kV) |
| Winding Material | 100% Copper |
| Impedance | 5.75% – 7.5% |
| Enclosure & Finish | NEMA 3R rated, utilizing ANSI C57.12.28 compliant anti-corrosion coatings |
| Coating Standard | ANSI C57.12.28 compliant anti-corrosion coatings |
| Official Certification Files | UL-CA-2228369-0, UL-US-2402197-0, UL-US-2586027-0 |
| Reference Dimensions | 71 in (L) x 36 in (W) x 35 in (H) |
| Reference Weight | 4,800 lbs (Fluid capacity: 180 gallons) |
| Lead Time & Warranty | 8-Week Delivery |
| Warranty | 36-Month Warranty |
Dedicated Engineering Support
Powering high-load applications requires precise planning. Send your exact single-line diagram (SLD) to our heavy-power engineering team so we can confirm breaker coordination and compliance requirements.
Our team will respond within 24 hours.