Panelboards UL 67

YunSen panelboards are designed to meet the specialized needs of any industrial or commercial electrical distribution system.

Reference lead time 8 weeks Initial feasibility feedback within 24 hours
  • Core Capabilities

    • YunSen panelboards are designed to meet the specialized needs of any industrial or commercial electrical distribution system. Lighting, Distribution, and Receptacle Panelboards are custom manufactured and engineered products designed to meet specific customer specifications and use cases. Standard panelboard configurations are also available.
      Full Customization and Design Flexibility Component and Metering Selection Options.Voltage: Up to 600Vac, 250Vdc maximum
      Ampacity: 100A to 600A
      65kA at 480V maximum
      UL listed CSA listed
      Single phase and three-phase
      Series ratings with upstream devices
      Main breaker, main lugs, subfed breaker - optional
      Vertically mounted main and sub-feed circuit breakers
      Up to 84 circuits in one panel
      Interiors available in silver plated copper or tin aluminum bus
      Complete line of UL listed interiors with 200% rated neutrals for non-linear loads
      Surge Suppression Equipment/Optional integrated TVSS
      Configured for sequence phase connections allowing complete flexible circuit arrangement (1-, 2- or 3-poles) to properly balance the electrical load on each phase.
      Lock and door opening mechanism includes a positive slide catch and right- or left-hand installation.
      Multi section boards – bolted together and bushed openings (horizontal and vertical)
      Standard or door in door trims
      ANSI 61 light gray standard finish, other colors available as option
      Stainless steel and aluminum available
      Up to 150A branch breakers
 

Single-Phase Pad-Mounted Transformer

Benefits

Voltage: Up to 480VAC, 250VDC maximum

Ampacity: 100A to 600A

65kA at 480Y/277VAC

65kA at 240V

UL or cUL listed

Single phase and three phase

Main breaker, main lugs, subfed breaker optional

10K thru 65K SCCR (AIC) – interrupting capacity

Vertically mounted main and sub-feed circuit breakers

Up to 84 circuits in one panel

Interiors available in silver plated copper or tin aluminum bus

An interior accepts bolt-on or plug-on branch circuit breakers

Complete line of UL listed interiors with 200% rated neutrals for non-linear loads

Surge suppression equipment/optional integrated SPD

Configured for sequence phase connections allowing complete flexible circuit arrangement (1-, 2- or 3-poles) to properly balance the electrical load on each phase

Lock and Door opening mechanism includes a positive slide catch and right- or left-hand installation

Multi section boards – bolted together and bush openings (horizontal and vertical)

Standard or door in door trims

ANSI 61 light gray standard finish, other colors available as optionStainless steel and aluminum available

We offer Title 24 panels for disaggregation of loadsUp to 100A branch breakers

Three-Phase Pad-Mounted Transformer

Technical Specifications

CDP Panelboards 


Voltage: Up to 600VAC, 250VDC maximum
Ampacity: 225A to 1200A
UL or cUL listed
Single phase and three-phase
Interrupt rating 25kA at 600V, 100kA at 480V, and 200kA at 240V
Series ratings with upstream devices
Interiors available in plated copper bus
Main breaker or main lugs
Fully rated or series rated
Selection includes most commercially available molded case circuit breakers from industry leading manufacturers
Standard or door in door trims
ANSI 61 light gray standard finish, other colors available as option
Stainless steel and aluminum enclosures available


Documentation


Product Sheets (PDF)/LV-Panelboards_UL67_02.


Manuals(PDF)/Panelboard_Installation_and_Maintenance_Manual.

Interested in this product?

Dedicated Engineering Support

Powering high-load applications requires precise planning. Send your exact single-line diagram (SLD) to our heavy-power engineering team so we can confirm breaker coordination and compliance requirements.

Our team will respond within 24 hours.