UL 845 MOTOR CONTROL CENTER (MCC)
YunSen UL 845 Motor Control Centers are modular pluginbucketstyle assemblies for centralized motorload and powerload control for industrial plants, waterwastewater facilities and manufacturing sites.
-
Core Capabilities
-
YunSen UL 845 Motor Control Centers are modular plug-in-bucket-style assemblies for centralized motor-load and power-load control for industrial plants, water-waste-water facilities and manufacturing sites. They can be custom-engineered or utilize a standard configuration to meet specific dimensional, motorstarting and protection requirements. Fully-integrated unit-bucket selections from leading manufacturers are available. Indoor and outdoor-rated enclosures are offered with multiple durable coating options.
Full Customization and Design Flexibility Starter, VFD & Metering Bucket Selection Options Fully Rated Horizontal & Vertical Bus.
-
Seismic Tested to Worst Case Response Spectrum Indoor and Outdoor Applications UL or cUL Listed; Meets NEMA ICS18 and CSA Standards.
-
-
-
Single-Phase Pad-Mounted Transformer
Benefits
Voltage- Up to 600VAC, Up to 1000VDC maximum rating (per UL845 scope)
Ampacity- Horizontal main bus rating: 600A-4000A; vertical bus rating: 300A-850A
Bus short-circuit bracing standard up to 65kAIC; optional 100kAIC @480V with suitably-rated components
NEMA Type1, Type12, Type3R enclosures
Paint ANSI 61-Standard, other colors, stainless-steel enclosures available as options
Front accessibility standard; front-and-rear accessible cabinet designs available as option
Modular plug-in bucket units for hot-swap maintenance without full MCC shutdown
Unit bucket types: non-reversible / reversible starters, combination motor controllers, VFD, soft-starters, feeder breakers and metering buckets
Custom sheet-metal and bus layout flexibility for cable entry and bus-duct connections
Extensive motor-protection and monitoring accessories available
Silver-plated copper horizontal and vertical busbars
Integrated neutral bus and ground bus systems
Tested to short-circuit withstand ratings per UL845 configuration standards
Rigid frame construction isolating bus and bucket assemblies from MCC enclosure
Metering compartments built to applicable Utility standards
Variety of fully integrated bucketunit options including motor starters, VFD, softstarters, feeder protection, automation, metering and remote monitoring
MCC fed by cables or bus duct
Series-rated configurations with upstream over-current-protection devices
Thermal-magnetic, electronic motor-protection devices with standard or high kAIC interrupting capability, 80% or 100% rated
All commercially available UL Listed MCC bucket-unit options for motor and feeder loads
Optional arc-resistant construction complying with IEEE C37.20.7
Built-in communication supporting Modbus-TCP/RTU, EtherNet/IP for remote monitoring & diagnostics
Seismic qualified assemblies tested to worst-case response spectrum
Value-engineered bucket-unit selections optimized for project motor-load schedules
Technical Specifications
UL 100kAIC bus bracing rating at 480V with suitably-rated bus and bucket assemblies.Series-rated combinations with upstream protective devices. Seismic tested per IEEE-693 and ICC-ES-AC156. Powder-coated enclosures with enhanced salt-spray resistance performance.
YunSen DIfference
Fully-rated horizontal & vertical bus designed based on density and temperature-rise criteria .Seismic-qualified MCC assemblies for critical-process installations .Enclosures built for application-specific dimensions with advanced powder-coating finishing exceeding standard salt-spray requirements .Motor-starter, drive and metering-bucket selections based on value-engineering for each application and optimized to meet motor-schedule and project specifications.
YunSen MCC assemblies are UL-listed to UL845 standard, comply with NEMA ICS-18 and CSA-C22.2 norms. Uses UL-listed MCC unit-bucket assemblies. YunSen UL845 Motor Control Centers meet seismic testing requirements as outlined by IEEE-693 and ICC-ES-AC156.
Dedicated Engineering Support
Powering high-load applications requires precise planning. Send your exact single-line diagram (SLD) to our heavy-power engineering team so we can confirm breaker coordination and compliance requirements.
Our team will respond within 24 hours.