MEDIUM VOLTAGE SWITCHGEAR
YunSen Medium-Voltage Switchgear are metal-clad / metal-enclosed assemblies for primary power distribution, protection and switching for utility, industrial, datacenter, mining and large-commercial installations.
-
Core Capabilities
-
YunSen Medium-Voltage Switchgear are metalclad / metalenclosed assemblies for primary power distribution, protection and switching for utility, industrial, data-center, mining and large-commercial installations. They can be customengineered or utilize a standard configuration to meet specific dimensional, protection and metering requirements. Fully-integrated component selections from leading manufacturers including vacuum circuit breakers, protective relays and metering instruments are available. Indoor, outdoor kiosk-style and container-type substation enclosures are offered with multiple durable coating options.
Full Customization and Design Flexibility Component and Metering Selection Options.Full Customization and Design Flexibility.
-
Protection Relay & Metering Selection Options Fully Rated Main & Sectional Bus.
-
Seismic Tested to Worst Case Response Spectrum.
-
Indoor and Outdoor KioskType Applications IEEE, ULrecognized and cUL Listed; Meets ANSI, NEMA and CSA Standards.
-
-
-
Single-Phase Pad-Mounted Transformer
Benefits
Voltage- 4.76kV up to 38kV maximum system voltage class
Ampacity- Main bus rating: 630A to 4000A
Short-circuit interrupt rating up to 40kA rms symmetrical; short-time withstand 1-3-second duration
Indoor metal-clad compartments; outdoor kiosk-style NEMA-rated enclosures
Paint ANSI standard finish – Standard; stainless-steel enclosure available as option
Front accessibility standard; front-and-rear accessible cabinet designs available as option
Compartmentalized metal-clad structure with isolated bus, breaker, cable and control compartments - Draw-out vacuum circuit-breaker units with mechanical and electrical safety interlocks
Custom sheet-metal and bus layout flexibility for bus duct, transformer and cable-incoming connections
Extensive protective relay, metering and control-device accessories available
Silver-plated copper busbars as standard, alternative bus-plating options available
Bus withstand ratings matched to system power-frequency and lightning-impulse insulation levels
Tested for short-time withstand fault duties per IEEE standards
Rigid metal-clad frame construction isolating bus and breaker assemblies from outer enclosure
Metering and protection compartments built to applicable Utility standards
Variety of fully integrated component options including vacuum breakers, over-current & earth-fault protection relays, power-quality monitoring, SCADA remote-control interfaces
Switchgear fed by power cables or bus duct
Main-tie-main schemes, automatic bus transfer configurations supported
Optional Internal-Arc Classification (IAC) construction for personnel safety
Seismic qualified assemblies tested to worst-case response spectrum
Value-engineered component selections optimized for project specifications
Technical Specifications
IEEE-recognised vacuum circuit-breakers with suitably rated main bus and compartment structures.Seismic tested per IEEE-693 and ICC-ES-AC156.Powder-coated enclosure finish with enhanced salt-spray resistance performance.
YunSen DIfference
Fully-rated bus designed based on short-time withstand and temperature-rise criteria .
Seismic-qualified switchgear assemblies for critical power installations .
Enclosures built for application-specific dimensions with advanced powder-coating finishing exceeding standard salt-spray requirements .
Protection, metering and control-component selections based on value-engineering for each application and optimized to meet project specifications.
YunSen Medium-Voltage Switchgear conforms to IEEE C37.20.2 metal-clad switchgear standard, NEMA SG-5, CSA C22.2 No.31-14. Uses IEEE-recognized vacuum circuit-breakers. YunSen Medium-Voltage. Switchgear meet seismic testing requirements as outlined by IEEE-693 and ICC-ES-AC156.
Dedicated Engineering Support
Powering high-load applications requires precise planning. Send your exact single-line diagram (SLD) to our heavy-power engineering team so we can confirm breaker coordination and compliance requirements.
Our team will respond within 24 hours.