Low Voltage Switchboards UL 891
YunSen UL 508A industrial control panels integrate power, control, automation, protection, and operator interfaces for machinery, process systems, packaged equipment, utilities, and building services.
-
Core Capabilities
-
Switchboards can be custom designed or utilize a standard configuration to meet specific dimensional and electrical requirements. They can include fully integrated component options from leading manufacturers, including automatic transfer switches, SPD, distribution transformers, and PLC or relay based transfer schemes, Automation, Metering and Monitoring. Circuit breakers and fusible switches can be group or individually mounted. Indoor and outdoor enclosures are available in a wide range of durable color finishes.
Full Customization and Design Flexibility Component and Metering Selection Options.
-
Fully Rated Bus Based on Density Ratings.
-
Seismic Tested to Worst Case Response Spectrum.
-
Indoor and Outdoor Applications UL or cUL Listed; Meets ANSI, IEEE, and NEMA Standards.
-
-
-
Single-Phase Pad-Mounted Transformer
Benefits
Voltage - Up to 600VAC, Up to 250VDC maximum
Ampacity - 400A to 12,000A maximum bus rating
Switchboard ratings through 12,000A, 200kA up to 480V, 100kA up to 600V
Type 1 or 3R enclosures
Paint ANSI 61 – Standard, other colors available as options
Front, rear, and side accessibility
Devices can be individually (vertically) or group (panel horizontally) mounted
Custom sheet metal and bus flexibility for busway and transformer connections
Extensive protective device accessories available
Silver-plated copper bus, or tin-plated aluminum bus, or optional tin plated or bare copper
1000A per sq in. fully rated copper bus systems
750A per sq in. fully rated aluminum bus systems
Tested to short circuit rating of 3 cycles (.05sec.) or to immediate trip of tested OCPD and braced to UL configuration standards
Rigid frame construction isolating bus and breaker assemblies from enclosure
Metering compartments built to applicable Utility standards
Variety of fully integrated component options available including automatic transfer switches, SPD, distribution transformers, and PLC or relay based transfer schemes, Automation, Metering and Monitoring
Switchboard fed by cables, cable bus, bus duct, or transformer
Fixed-mount or draw-out breakers for both mains and feeders
Group mounted, fix-mounted fusible switch mains and feeders or combination of fixed mounted breakers and fusible switches
Thermal magnetic, electronic circuit breakers with standard, high kAIC or current limiting capability, 80% or 100% rated
All commercially available UL Listed options on circuit breakers and fusible switches
Technical Specifications
UL 200kA ratings at 480V through 12,000A with suitably rated components (Group mounted circuit breakers or fusible switches are 200kA rating at 240v or 100kA rating at 480v).UL 100kA at 600V from 2000A to 12,000A ratings with suitably rated components.UL 100kA ratings for commercial multi- metering with suitably rated MCCB Seismic tested.
YunSen DIfference
UL 100kA at 600V from 2000A to 12,000A ratings with suitably rated components UL 100kA ratings for commercial multi- metering with suitably rated MCCB.Seismic tested.Fully rated bus is based on density ratings, not UL heat rise tests, resulting in greater efficiency and lower operating temperatures.All enclosures are designed for specific application with improved dimensional flexibility and finished using state of the art powder coating system providing an indoor finish that exceeds the 1500 hour salt spray testing requirement for outdoor equipment to 3000 hours.Component and metering selections are based on value engineering for the application and optimized to meet specifications.
YunSen Switchboards meet or exceed applicable industry standards, including UL891, CSA, NEMA standards PB-2, NEMA 1 and NEMA 3R enclosures. Uses UL489 or UL1066 listed breakers.
YunSen Distribution Switchboards meet seismic testing, circuit requirements as outlined by IEEE344 and ICC-ES-AC156.
Dedicated Engineering Support
Powering high-load applications requires precise planning. Send your exact single-line diagram (SLD) to our heavy-power engineering team so we can confirm breaker coordination and compliance requirements.
Our team will respond within 24 hours.